Disposable Twisted Subdermal Corkscrew Needles
P/N: 83019150120
The Sinelink Twisted subdermal needles are specialized electrodes designed for neurodiagnostic procedures, particularly in intraoperative monitoring (IOM), electroencephalography (EEG), and evoked potentials (EP).

EMG Medical Disposable Single Sterile Corkscrew Needle Electrode
Introduction
These needles provide superior stability and signal quality due to their unique twisted design, making them an essential tool in both clinical and research settings.
Specification
|
Product Name |
Subdermal Corkscrew Rotating Electrode Needle |
|
Product Number |
83019150120 |
|
Electrode |
Stainless steel spiral needle |
|
Wire material |
PVC |
|
Connector Type |
DIN42802 / pin |
|
Color code |
|
|
Patibility |
Compatible with standard EEG,IOM,EP |
|
Certificate: |
ISO 13485:2016 |
Features and application
Key Features
Design
- Twisted Needle Shape: The twisted design enhances the electrode's stability once inserted, reducing movement and maintaining consistent contact with the skin.
- Subdermal Placement: These needles are designed to be inserted just below the skin, ensuring minimal discomfort and optimal signal acquisition.
Materials
- Stainless Steel Construction: Ensures durability and biocompatibility, reducing the risk of allergic reactions or infections.
- Flexible Lead Wires: High-quality, flexible lead wires connect the needle to the monitoring equipment, ensuring reliable signal transmission.
Connectivity
- Touch-Proof Connectors: Standard 1.5 mm touch-proof connectors for safe and secure attachment to EEG and IOM equipment.
- Color-Coded Leads: Helps in easy identification and correct placement during procedures.
Benefits
- Superior Signal Stability: The twisted design minimizes movement, providing stable and consistent signal quality.
- Ease of Use: The design allows for easy insertion and secure placement, reducing setup time and enhancing workflow efficiency.
- Patient Comfort: Subdermal insertion is minimally invasive, improving patient comfort during long monitoring sessions.
- Single-Use Option: Many twisted subdermal needles are designed for single use, ensuring sterility and reducing the risk of cross-contamination.
Applications
Clinical
- Intraoperative Monitoring (IOM): Essential for monitoring neural pathways during surgeries to prevent nerve damage.
- Electroencephalography (EEG): Used to measure electrical activity in the brain for diagnosing conditions like epilepsy.
- Evoked Potentials (EP): Helps in assessing the brain's response to sensory stimuli.
Research
- Neuroscience Studies: Widely used in research labs for studying brain functions and neural responses.
- Brain-Computer Interface (BCI) Development: Integral in developing systems that facilitate direct communication between the brain and external devices.
Product Specifications
- Needle Length: Typically ranges from 12 mm to 15 mm, depending on the specific application.
- Lead Wire Length: Common lengths include 1.2 m, 1.5 m, 2.0 m and 2.5 m.
- Connector Type: 1.5 mm touch-proof connectors, compatible with most neurodiagnostic equipment.
Usage Instructions
- Preparation: Clean the area where the needle will be inserted to ensure optimal contact and reduce the risk of infection.
- Insertion: Carefully insert the twisted needle just below the skin at the desired location.
- Connection: Attach the lead wire to the corresponding connector on the monitoring equipment.
- Monitoring: Begin the monitoring process, ensuring the needle remains stable and the signal quality is maintained.
- Removal: After the procedure, carefully remove the needle and dispose of it if it is a single-use product.
Details



Packaging
EO Individually packaged after sterilization.
FAQ
Q: What are Disposable Twisted Subdermal Corkscrew Needles?
Q: How are Disposable Twisted Subdermal Corkscrew Needles used?
Q: What are the benefits of using Disposable Twisted Subdermal Corkscrew Needles?
Single Use: Being disposable reduces the risk of cross-contamination and infection.
Ease of Use: Quick and easy to insert and remove, enhancing efficiency in clinical settings.
Patient Comfort: Designed to minimize discomfort during insertion and use.
Q: In what procedures are Disposable Twisted Subdermal Corkscrew Needles commonly used?
Electroencephalography (EEG): To record electrical activity in the brain for diagnosing neurological conditions like epilepsy.
Evoked Potentials (EP): To measure the brain's response to specific sensory stimuli.
Q: Are there any specific precautions to take when using Disposable Twisted Subdermal Corkscrew Needles?
Sterility: Maintain sterile conditions during insertion and removal to prevent infections.
Single Use: Do not reuse disposable needles to avoid the risk of cross-contamination and ensure patient safety.
Q: What materials are Disposable Twisted Subdermal Corkscrew Needles made from?
Q: What are the common specifications for Disposable Twisted Subdermal Corkscrew Needles?
Lead Wire Length: Available in lengths such as 1.2 m, 1.5 m, and 2.0 m.
Connector Type: Standard 1.5 mm touch-proof connectors compatible with most EEG and IOM equipment.
Q: Where can I purchase Disposable Twisted Subdermal Corkscrew Needles?
Hot Tags: Disposable Twisted Corkscrew Subdermal Needles Cable, China Disposable Twisted Corkscrew Subdermal Needles Cable manufacturers, suppliers, factory, single corkscrew needle electrode, disposable twisted subdermal corkscrew needles, corkscrew electrode, emg medical disposable single sterile corkscrew needle electrode