Your Professional Jumper Connector Linked Ears Supplier

Shenzhen Sinelink Electronics Co., Ltd. is a professional provider specializing in a comprehensive range of medical accessories and integrated solutions. Our main products include brain electrodes, surgical connecting cables, ECG, EMG, EKG, IOM, and blood oxygen probes, as well as other medical accessories such as wires, nerve electrode lines, medical-grade plastic products, epidermal electrodes, myoelectrodes, and invasive pressure sensing cables.

Custom Service

All of our products are designed and manufactured to meet or exceed the specifications and performance standards of original equipment manufacturers (OEMs), ensuring compliance with warranty requirements.

01

Professional Team

The company places great emphasis on the recruitment and development of professional talent. We have established a high-quality, multidisciplinary team integrating research and development, management, and manufacturing, which ensures the delivery of high-quality products at competitive prices.

02

Product Quality Assurance

All products undergo rigorous quality control and testing procedures to ensure compliance with international standards and customer expectations. In the event of quality issues arising under normal usage conditions, we will provide appropriate remedies based on the specific circumstances.

03

One-stop Solution

Sinelink offers a one-stop solution for all patient monitoring accessories. As specialists in this field, we are committed to providing qualified and reliable products tailored to your needs.

04

 
  • Stackable Electrode Jumper
    EEG Stackable Electrode Jumper Cable. P/N:82029015029. Reference Jumper 1.5mm Male to 1.5mm Female . 1.5mm DIN42802 safety connector. TPU,10color, 6 inches(15cm). Certificate : ISO 13485:2016.
    read more
 

Parameter

 

P/N

82029015029

Length

6 inches(15cm), other lengths available upon reques

Socket

1.5mm DIN42802 safety connector

Wire diameter

1.65mm

Color

productcate-188-28

Shelf life

12 months

Material

TPU

Compatibility

Compatible with most EEG systems and amplifiers

 

Key Features of Jumper Connector Linked Ears

 

High-Quality Materials

Made from sturdy and pliable materials to guarantee longevity and dependable functionality.

01

Touchproof Connectors

With 1.5mm touchproof connectors, it guarantees user safety and works with a variety of EEG devices.

02

Stackable Design

Enables the series connection of multiple cables, giving signal routing and electrode positioning flexibility.

03

Optimal Length

Available in multiple lengths to accommodate different setup requirements and guarantee minimal signal interference, including the widely used 6-inch (15cm) version.

04

Versatile Use

Suitable for research studies, neurofeedback, and clinical diagnostics, among other applications.

05

 

Applications of Jumper Connector Linked Ears

Clinical EEG monitoring

A method used in clinics and hospitals to track patients' brain activity.

Neurofeedback Training

Accurate biofeedback and training sessions require neurofeedback practitioners to undergo neurofeedback training.

Research and Development

Used in labs for investigations into brain-computer interfaces, neurological research, and cognitive studies.

 

Precautions for Using Jumper Connector Linked Ears

 

 

Frequent Inspection

To ensure optimal performance, periodically inspect the cable for indications of wear and tear.

 

Clean Handling

To avoid signal degradation, make sure connectors are kept dry and clean.

 

Appropriate Storage

To preserve the cable's flexibility and extend its life, keep it in a cool, dry location.

 

 

(5)

 

Information Required When Making an Inquiry

3D drawings(STEP, CAD, SOLID Works, PROE, DXF and PDF)


Material requirement (include contact material and insulation material.)


Surface treatment


Quantity or Consumption (per order/ per month/ annual)


Any special demands or requirements, such as packing,labels, delivery, etc.

 

Packaging and Shipping

 

Packaging

Wrap with transparent PE plastic bag,each bag with 1 piece.

Shipping

We will help you to choose the best shipping way according to your detail requirements. By sea, by air, or by express, etc.

 

 
 
Pre Sales And After-Sales Support
01.

Technical Support

We have a professional technical support team, ready to answer your technical questions during product use. No matter what difficulties you encounter, just contact us and we will be happy to provide you with a solution.

02.

Product Quality Assurance

We promise that all the products we sell will undergo strict quality testing to ensure that the products you purchase meet international standards and your expectations. If quality problems occur under normal use, we will provide corresponding solutions based on the specific situation.

03.

Logistics Tracking

In order to ensure that you can receive the goods in time, we will provide you with full logistics tracking services. You can check the transportation status of the goods at any time through the tracking number provided by us.

04.

After-Sales Service Consultation

If you have any questions or suggestions during the cooperation process, please feel free to contact us. We will respond promptly and provide you with satisfactory answers and solutions.

 

Our Customers
 
productcate-334-334
productcate-338-338
productcate-261-260
productcate-353-352
modular-1

 

Certificate
productcate-376-282
productcate-376-282
productcate-376-282
productcate-376-282

 

FAQ

Q: What is the difference between bipolar and monopolar EEG?

A: The bipolar transverse montage links adjacent electrodes in a chain, going from left to right. Monopolar, or referential montages, connect each electrode to a single referential point.

Q: What is an EEG behind the ear?

A: In ear-EEG, the electrodes are exclusively placed in or around the outer ear, resulting in both a much greater invisibility and wearer mobility compared to full scalp electroencephalography (EEG), but also significantly reduced signal amplitude, as well as reduction in the number of brain regions in which activity can ...

Q: Why is a jumper needed in EEG monitoring?

A: Jumper is used to block non-EEG signal or combine different inputs together.

Q: Can I use any amplifier with Electrode Jumper Cables?

A: The majority of electrode jumper cables work with common touch-proof connector EEG amplifiers. To make sure compatibility, it's crucial to review your amplifier's specifications. Certain amplifiers come equipped with internal features that could eliminate the need for external jumpers.

Q: Are Electrode Jumper Cables reusable?

A: Yes, Sinelink electrode jumpers are designed to be reusable, but they must be cleaned and maintained in time to ensure their service life and functionality. Do not use them when they appear worn.

Q: Can an EEG show intelligence?

A: The electroencephalogram (EEG) reflects stable individual differences in brain function and therefore can be a powerful instrument for exploring the biological basis of intelligence.

As one of the leading jumper connector linked ears manufacturers and suppliers in China, we warmly welcome you to wholesale jumper connector linked ears for sale here from our factory. All customized products are with high quality and competitive price.

stackable electrode jumper, jumper connector linked ears, electrodes for saddle stimulation
Send Inquiry