Reusable Gold Painted EEG Cup Electrodes

Reusable Gold Painted EEG Cup Electrodes
Details:
Gold Coated Reusable Cup Electrodes For EEG
P/N: 81001100003
10mm copper gold-plated EEG electrode cup with holes
PVC cable, available in 1.0m, 1.5m, 2.0m, 2.5m lengths
Standard DIN42802 plug, optional DIN 1.5mm / 2mm plug
Send Inquiry
Download
Description
Technical Parameters

Gold Coated Reusable Cup Electrodes For EEG

P/N: 81001100003

 

The Sinelink EEG electrodes are featured low impedance with stable signal transmission.

With a cast design and precision craftsmanship, Sinelink EEG electrodes is optimized for longtime of use.

 

image001001
image003001
image005001
image007001

 

Gold Coated Reusable Cup Electrodes For EEG

 

Introduction

 

Each Sinelink EEG cup electrode is tested mechanically and electrically to ensure long life.

To meet different requirements on using, we offer multiple choice for cups and coating including silver and copper.

Size of the cup ranging from 10mm (for adult) and 6mm (for child).

Wires and connectors can also be customized.

 

Specification

 

Cup material

Silver / Copper

Cup coating

Au

Cup type

Casted / Stamped

Cup size

10mm (for adult) / 6mm (for child)

Wire material

TPU / PVC / Teflon

Connector Type

DIN42802 / pin

Color code

image009

Patibility

Compatible with standard EEG systems and amplifiers

Certificate:

ISO 13485:2016

 

Features and application

 

  • Casted / Stamped cup design
  • Child / adult option
  • Gold coat thickness and connector customization
  • 10 colors lead wire
  • Tangle free lead wire
  • Ideal for EEG, EP or PSG monitoring
  • 3 years guarantee

 

Details

 

image011
Connector customization
image013
Casted / Stamped cup design
image015
10 colors tangle free lead wire

 

Packaging

 

Cup electrodes are usually packed in multiple configurations:

Individual packaging: Typically, a single cup electrode is enclosed in its own packaging. In addition to preventing damage during transportation and storage, this packaging aids in maintaining sterility. Usually, it's made up of a tiny plastic or foil bag.
Sets or kits: It's common to find cup electrodes offered in sets or kits. These kits usually come with many cup electrodes in various sizes or colors along with the required add-ons like tape, gel, and wires. They are enclosed in either aluminum foil or plastic bags.
Then arranged for convenience of storage and transportation in a small box or box.

 

FAQ

 

Q: How can I get a quote?

A: Please contact us through the page, our message system, Please contact us via the contact details on our website or leave your contact details,our sales representative will contact you soon.

Q: How quickly do you response?

A: Normally we will response a request within 2 hours.

Q: How should I do if I need customization?

A: Please refer to your sales representative for what you need, we will offer design or material choice service for you.

Q: What shipping agent can I use?

A: According to product feature, you could choose the shipping agent as you like. We are able to sent your products through most of international express as well as air/sea agents.

Q: Where to buy cup electrodes?

A: You can contact me directly to purchase,we offer several types of cup electrodes.

Q: How many cup electrodes are needed for EEG?

A: Clinical EEG typically recommends the use of 16 cup electrodes, which can record from multiple scalp locations and capture most normal and abnormal EEG patterns. However, different diagnostic procedures or monitoring other physiological processes may require additional electrodes, and we can customize different numbers of cup electrodes according to your needs.

Q: How to clean cup electrodes?

A: Maintaining cup electrodes' durability and efficacy requires regular cleaning. Here's a general cleaning guide for them:
Before cleaning, make sure the electrodes are unplugged from all wires and gadgets.
Remove Gel: Use a soft, damp cloth or tissue to gently wipe away any gel or residue left over from a previous use. If necessary, you can also apply a mild soap solution.
Rinse: To get rid of any last bits of gel or debris, rinse the electrodes under lukewarm running water. Use of hot water should be avoided as it could harm the electrodes.
Clean: The electrodes can be cleaned by soaking them for ten to fifteen minutes in a 70% isopropyl alcohol solution. This aids in eliminating any germs or bacteria that could.
Rinse Again: To get rid of any remaining alcohol, give the electrodes another quick rinse under running water after disinfecting.
Dry: Before storing or reusing the electrodes, let them air dry entirely. To avoid damaging them, do not use heat to dry them.
Storage: After the electrodes are dried, keep them out of the direct sunlight and dust in a clean, dry place.
Examine: Check for wear or damage on the electrodes before to each use. To guarantee precise and secure measurements, replace the electrodes if you see any cracks, tears, or other problems.

 

Hot Tags: Reusable Gold Painted EEG Cup Electrodes, China Reusable Gold Painted EEG Cup Electrodes manufacturers, suppliers, factory, medical cable accessories, esu accessories forceps, eeg electrode, silver silver chloride cup electrodes, 1 5 mm touch proof connectors for eeg electrodes, surface electrodes

Send Inquiry