Silver/Silver Chloride Cup Electrodes

Silver/Silver Chloride Cup Electrodes
Details:
Silver/Silver Chloride Cup Electrodes
P/N: 81001100010
Disc Type: 10mm ABS/silver Chloride
PVC Cable, Length 1.0m/1.5m/2.0m/2.5m
Can be used with all popular gels, pastes and adhesives
Certificate : ISO 13485:2016
12color/bag
Send Inquiry
Download
Description
Technical Parameters

Disposable AgCl ABS EEG deep cup electrode wire

P/N:

The Sinelink disposable EEG electrodes are featured low impedance with stable signal transmission.

With deep cup design and precision craftsmanship, Sinelink disposable EEG electrode is optimized for longtime of use.

 

image001

 

Disposable AgCl ABS EEG deep cup electrode wire

 

Introduction

 

Each Sinelink disposable EEG cup electrode is tested mechanically and electrically to ensure long life.

To meet different requirements on using, we offer multiple choice for wires and connectors.

 

Specification

 

Cup material

ABS

Cup coating

AgCl (Silver chloride)

Cup size

10mm

Wire material

TPU / PVC / Teflon

Connector

DIN42802 / pin

Color code

image003

 

Features and application

 

  • Deep cup design
  • 10 colors lead wire
  • Tangle free lead wire
  • Ideal for EEG, EP or PSG monitoring
  • 3 years guarantee
  • Compatible with irradiation and alcohol sterilization

 

Details

 

image005
Connector customization
image007
Deep cup design
image009
10 colors tangle free lead wire

 

Qualification

 

image011

 

Sinelink is comply with ISO13489:2016 and has the ability to design and manufacture a full range of neurodiagnostic suppliers. With years' experiences, we are able to serve customers from all over the world and gain fabulous reputation from our cooperators.

 

FAQ

 

Q: Why are AgCl electrodes used in EEG?

A: The silver chloride (AgCl) coat used for surface of electrode in EEG is due to its low electrical impedance and stability.

Q: How long an AgCl coated electrode cup can be used?

A: Normally 6 months. It could be used more than 1 year in case of correct and expert application.

Q: How should I store the cup electrodes?

A: Avoid sunlight under temperature between 10-25℃(50-77℉) and humidity 0-80%, keep the package intact before usage.

Q: What are the benefits of using disposable vs. reusable AgCl electrodes?

A: By doing away with the need for cleaning and sterilization, disposable AgCl electrodes lower the possibility of cross-contamination while also saving time.

Q: Why is AgCl used in these electrodes?

A: Because of its low impedance and exceptional signal stability, which lowers noise in recorded signals, silver/silver chloride (AgCl) is used. AgCl electrodes are therefore perfect for gathering precise and unambiguous bioelectrical data.

Q: How do you apply and use AgCl coated cup electrodes?

A: Usually, conductive gels or pastes are used to apply these electrodes in order to guarantee proper skin contact and signal quality. For accurate readings, the lead wires must be positioned in accordance with standard protocols when connected to a recording device.

 

Hot Tags: silver/silver chloride cup electrodes, China silver/silver chloride cup electrodes manufacturers, suppliers, factory, monopolar nerve stimulation probe with 0 8 mm probe tip, electrosurgical cables, eeg dry electrode, disposable hand control esu pencil, disposable electro cautery surgery pencil, disposable ball tip direct nerve stimulator probe