ECG/EKG chest Suction Ball Electrode
P/N: 82000000131
An EKG electrode is a piece of medical equipment that connects the heart's electrical signals to an EKG machine. The heart's rhythm is then evaluated and any anomalies are found by recording and analyzing these data. Suction-cup ball ECG electrodes provide a non-adhesive alternative to traditional adhesive pads that adhere to the patient's skin, improving both performance and patient comfort.

Adult Suction Cup Bulb and Multicolor Limb Clamp AGCI ECG EKG Electrodes
Introduction
Each Sinelink Reusable Suction Cup Electrodes Bulb is mechanically and electrically tested to ensure a long service life.
To meet different usage requirements, we offer a variety of cup body and coating options, including nickel-plated copper, Agcl-plated copper
The color of the suction ball is blue, gray or other customized colors are also available.
Specification
|
Product Name |
Multi-functional Suction cup Electrodes |
|
Product Number |
82000000131 |
|
Material |
Medical-grade PVC and Copper nickel plating, copper plating Agcl |
|
Color |
Transparent or customizable upon request |
|
Size |
Diameter 3.5 cm |
|
Weight |
Approximately 10 grams per electrode |
|
Patibility |
Suitable For All Type of Ecg Machine. |
|
Certificate: |
ISO 13485:2016 |
|
Packing |
Sets of 6 or 12 electrodes |
Features and application
- High-conductivity materials for accurate and clear ECG signal transmission
- Child / adult option
- Latex-Free: Safe for patients with latex allergies
- Adhesion: Secure suction-based attachment eliminates the need for adhesives
- Compatibility: Universal clip connector compatible with most standard ECG machines
- Reusability: Designed for multiple uses with appropriate cleaning and maintenance
- Certifications: ISO 13485 for medical devices
- Ideal for EEG, EP or PSG monitoring
- 3 years guarantee
Details



Usage Instructions
Application
- Preparation: Clean the skin site to remove oils and debris.
- Attachment: Press the suction cup firmly onto the cleaned site.
- Connection: Attach the electrode to the ECG machine using the universal clip connector.
Removal
- Release: Gently lift the edge of the suction cup to release the seal.
- Cleaning: Clean the electrode as per recommended guidelines.
Cleaning and Maintenance
Post-Use Cleaning: Wipe with a soft cloth dampened with a mild disinfectant.
Deep Cleaning: Submerge in a mild disinfectant for 10 minutes, rinse with sterile water, and air dry.
Inspection: Regularly check for wear or damage. Replace if necessary.
Storage: Keep in a cool, dry place away from direct sunlight and extreme temperatures.
FAQ
Q: How can I get a quote?
Q: How quickly do you response?
Q: How should I do if I need customization?
Q: What shipping agent can I use?
Q: Where to buy Chest Suction ECG EKG Electrode electrodes?
Q: What should I do if a Suction Cup Bulb ECG Electrode loses suction?
1)Reposition the electrode by cleaning the site and ensuring it is dry before reapplying.
2)Check for any debris on the suction cup and clean it if necessary.
3)Ensure proper technique is used when pressing the suction cup onto the skin to create a secure seal.
Q: Are Suction Cup Bulb ECG Electrodes safe for patients with latex allergies?
Q: Are Suction Cup Bulb ECG Electrodes reusable?
Hot Tags: suction cup bulb ecg electrode, China suction cup bulb ecg electrode manufacturers, suppliers, factory, electrodes for saddle stimulation, ionm 2 channel laryngeal surface, button control electrosurgical pencil, subdermal needle electrode, universal laparoscopic monopolar cable 8 0 3 0 female, suction cup bulb ecg electrode