Reusable Laparoscopic Bipolar Cable For R.Wolf

Reusable Laparoscopic Bipolar Cable For R.Wolf
Details:
P/N: 79063300058
2* 4.0mm banana plug, R.Wolf® type connector
Cable Length 3.0m
Reusable, Monopolar, NON-STERILE condition
Certificate : ISO 13485:2016 ,Packing:1Pcs/Pkg
Send Inquiry
Download
Description
Technical Parameters

Reusable laparoscopic Bipolar cable for R.Wolf


P/N: 79063300058
2* 4.0mm banana plug, R.Wolf® type connector

Cable Length 3.0m
Reusable, Monopolar, NON-STERILE condition
Certificate : ISO 13485:2016 ,Packing:1Pcs/Pkg

 

product-616-616
product-800-800

 

Reusable Bipolar Cable for R.Wolf

 

Introduction

 

The Slinelink bipolar cable is applied to R.Wolf® Instruments for laparoscopic and compatible with Aesculap®, Erbe® ICC International, Conmed® ACMI®, Codman®, Olympus®, Valleylab®, US Standard® and so on.

Bipolar cable for R.Wolf instruments consists of R.Wolf® type connector and 2- Φ4mm banana plug, and the 3m double single-core paralleled wire of silicone material.

The product connects High Frequency Power Supply and neutral electrodes, which offers high frequency power for surgical instrument.

As R.Wolf-compatible reusable bipolar electrosurgical cable, it also supports customization to the required length besides the length of 3m.

 

Specification

 

Product name

Bipolar cable for R.Wolf instruments

Item no.

79063300058

Generator side

2- Φ4mm banana plug

Instrument side

R.Wolf® type connector

Cable length

10ft(3.0m)

Wire material

Silicone, gray

Generator type

Multi-brand compatibility

Disinfecting type

Medical alcohol

Shelf life

3 years

Certificate

ISO 13485:2016

 

Features and application

 

  • Durability and adaptability:

Plastic injection on the basis of silicone wire - as the electrosurgical cable, it is resistant to high temperature, high pressure and wear so that it can be very well adapted to the surgical environment.

  • Design for patibility:

The design of two oval grooves on the surface of R.Wolf® type connector makes it easier to connect and disconnect the instrument.

  • Tangle free lead wire:

The wire of bipolar cable for R.Wolf instruments is soft and flexible and the design of double single-core paralleled wire and the wire nail is simple and clever, which avoid tangling during procedures and also make storage and sorting more convenient.

  • Repeatability and disinfection:

Disinfect with medical alcohol before and after each use is necessary for reusable cable, which also can extend its service life as soon as possible.

  • 100% testing before storage:

Continuity test - 100% continuity test ok, no short-circuit / disconnection / dislocation, conduction impedance <1Ω;

Hi-pot test - The voltage between core and core withstand 1500V/50Hz/60s, leakage current less than 0.25mA (no breakdown, flicker, arc and other phenomena);

Strength - The force to pull out between plug and surgical equipment socket ≥12N, wire rod: 10Ibs(44.5N).

  • Comply with EU Directive 2011/65/EU.

 

Details

 

2001
Standard 4mm banana plug
product-800-800
R.Wolf® type connector
1001
Double paralleled
(with the wire nail)

 

FAQ

 

Q: What is a Reusable Bipolar Cable for Richard Wolf (R.Wolf)?

A: An electrosurgical generator and bipolar surgical instruments are connected by a medical device called a Reusable Bipolar Cable for Richard Wolf. Because it is reusable-that is, it can be cleaned and used repeatedly-it is an affordable option for a range of surgical procedures.

Q: How do I use a Reusable Bipolar Cable for R.Wolf?

A: An electrosurgical generator and bipolar surgical instruments are connected by a medical device called a Reusable Bipolar Cable for Richard Wolf. Because it is reusable-that is, it can be cleaned and used repeatedly-it is an affordable option for a range of surgical procedures.

Q: What procedures can be performed with a Reusable Bipolar Cable for R.Wolf?

A: Many minimally invasive surgical procedures, such as laparoscopic, endoscopic, gynecological, urological, and neurosurgical procedures, frequently use a Reusable Bipolar Cable for R. Wolf. It makes precise tissue coagulation and cutting easier, which is crucial for these kinds of operations.

Q: How do I sterilize a Reusable Bipolar Cable for R.Wolf?

A: According to the manufacturer's instructions, a reusable bipolar cable for R.Wolf should be sterilized. This usually entails giving the cable a thorough cleaning after every use and sterilizing it with an autoclave or an authorized chemical sterilant. Before storing the cable, make sure it is completely dry.

 

Hot Tags: reusable laparoscopic bipolar cable for r.wolf, China reusable laparoscopic bipolar cable for r.wolf manufacturers, suppliers, factory, medical disposable emg concentric needle electrodes, electrodes for saddle stimulation, brain electrode touch dry for eeg, disposable hand control esu pencil, eeg dry electrode, reusable monopolar ear clip

Send Inquiry